WorldDSL™ HDSL
Economical, Reliable, and Manageable E1 and Serial Data Deployment
Line and Universal Terminating Units
Element Doubler Unit
ADC's WorldDSL™ HDSL Solutions are designed for the copper cable-based E1 (G.703) and Serial
data (V.35, V.36,RS-530, and X.21) access needs of Global markets and are ideal for both telco
and enterprise networks. WorldDSL HDSL Line and Universal Terminating Units can be used
in a managed central office (CO) or enterprise data-center based type chassis or in single slot
enclosures. WorldDSL HDSL Element Doubler Units are used outdoors between the central office
and the customer to extend the range and reach of HDSL when needed.
WorldDSL HDSL is part of a fully manageable system. Using a VT100 compatible terminal or a PC,
the units can be managed via their local craft ports. When used in a WorldDSL Element Managed
Shelf (EMS) and an Element Management Unit (EMU), the entire system can be managed locally or
remotely through a dial-up modem or Ethernet network.
The HDSL line cards come in span powering Line Terminating Unit (LTU) and Universal Terminating
Unit (UTU) versions. The LTU central office unit is locally powered and can span power a remote
UTU version. The UTU card can be used universally as a locally powered CO/LTU or as a local or
span powered remote/Network Terminating Unit (NTU). LTUs and UTUs can be mounted in a
16-slot EMS or a single slot Element Remote Enclosure (ERE).
The WorldDSL HDSL Element Doubler Unit (EDU) can be used to greatly increase the service area
range. The EDU is line powered by a WorldDSL LTU. Up to two EDUs can be installed in a circuit,
each of which will extend the reach of the circuit. For example, if, based on the current circuit
noise and wire gauge, the reach is 3.2 Km, adding one EDU can extend reach to 6.9 Km and a
second can extend reach to 7.5 Km. The EDU is suitable for outdoor use and is mounted in one of
ADC's weatherproof enclosures such as the single HRE-602 (holds one EDU) or Radiator (holds 6
to 8 EDUs). The EDU features a front panel LED for easy verification of operation during installation
and troubleshooting that is externally visible when used with the HRE-602 enclosure. ADC's
doubler enclosures also feature integrated gas tubes for lightning and power cross protection.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
WorldDSL™ HDSL
Economical, Reliable, and Manageable E1 and Serial Data Deployment
Specifications
HDSL Interface
Line Code:
2B1Q
Line Rate:
1168 kbps on each pair
Output:
13.5 dBm 0.5 dB
Maximum Provisioning Loss:
Range:
35 dB at 292 kHz
See Figures 1, 2 and 3
HDSL Connector:
Secondary Protection:
LTU/UTU Protection Compliance:
See specific enclosure for external DSL interface connection type
Provided on LTU, UTU, and EDU
ITU-T K.20 and K.21 compliant when used in
ADC Chassis and Enclosures
EDU Protection Compliance:
EDU Primary Protection:
EDU Protection Compliance:
Other Compliances:
ITU-T K.17
Integrated gas discharge tubes when used in EDU enclosures
ITU-T K.17 when used in ADC enclosures
ETSI TS101135 and ITU-T G.991.1
E1 Interface
Line Code:
Data Rate:
Operation:
Blocking:
HDB3
2048 kbps
Full or fractional
Per 64 kbps channel
Idle Code Insertion:
Impedance:
Framing:
Connectors:
Timing:
User selectable word
120 Ω balanced or 75 Ω unbalanced
Structured with or without CRC-4 or unstructured
Both D15F (balanced) and BNC (unbalanced)
G.703 or external
Compliance:
ITU-T G.703, G.704, G.706, G.821, G.823, CTR12
Data Interface
User software selectable as:
Connector:
V.35, V.36, RS-530, X.21
D25F (adapters available)
Internal, external, Nx64k, HDSL
Net 2
Timing:
Compliance:
Performance Monitoring
HDSL:
E1:
Noise margin, pulse attenuation, ES, UAS
ITU-T G.821
Alarms:
Form C relay contacts
HDSL Loopbacks:
LTU or UTU local or remote towards Network or Customer EDU
towards Network
E1 and Serial Data Loopbacks:
Test Pattern:
Local or remote towards Network or Customer
PRBS generator and BER meter
Power
Input Power:
- 36 to -72VDC for LTU and UTU when locally powered
75VDC to 120VDC Tip to Ring for UTU or EDU when
span powered from LTU
Power Consumption:
5W for line or locally powered UTU
5W for LTU with line powering off
15W for LTU with line powering on
2.5W for line powered EDU
Physical
LTU and UTU Dimensions (HxWxD):
6.89" x 0.925" x 8.45" (175 mm x 24 mm x 215 mm)
Weight
LTU:
0.81 lbs. (0.37 Kg)
UTU:
0.61 lbs. (0.28 Kg)
EDU Dimensions (HxWxD):
EDU Weight:
2.6" x 1.46" x 6.5" (66 mm x 37 mm x 165 mm)
1.8 lbs. (0.82 kg)
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
LTU Chassis and Enclosures:
EDU Outdoor Enclosures:
EMS-830 L2 or EMS-832 L2 Central Office 16 slot shelf
ERE-811 L5 single slot desktop enclosure
HRE-602 L1 above ground, hold one EDU
RAD-AG30-8 above ground, vented, holds 4-6 EDUs
RAD-BA30-8 below ground, pressurized, holds 4-6 EDUs
RAD-AG30-16 above ground, vented, holds 8 EDUs
RAD-BA30-16 below ground, pressurized, holds 8 EDUs
Note: All Have Integrated Gas Discharge Tube protection
Environmental
Operating Temperature:
Storage Temperature:
Humidity:
-5º C to +50º C (LTU and UTU), -40º C to +65º C (EDU)
-40º C to +85º C
Up to 95% RH non-condensing
Regulatory
CE marked
EN60950
Safety:
Emissions and Immunity:
EN 300386-2
O r d e r i n g I n f o r m a t i o n
Description
Catalog Number
Line Terminating Unit, locally with span powering, E1+serial
LTU-804 L1C
(G.703+V.35, V.36, RS-530, X.21)
Universal Terminating Unit, locally or span powered by LTU, E1+serial
(G.703+V.35, V.36, RS-530, X.21)
UTU-804 L1C
EDU-840 L3
Element Doubler/Regenerator Unit, span powered by LTU, double-wide 239 mechanics
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
106805AE 11/08 Original
©
2008 ADC Telecommunications, Inc. All Rights Reserved
|