TOTAL ACCESS 234 SHDSL NTU
P/N 1200708L1
Quick Start Guide
CONFIGURE GATEWAY IP ADDRESSES/SUBNET MASK
CONNECT THE CONSOLE INTERFACE
Before connecting to the Total Access 234 console interface, you will need the following items: VT100
terminal or PC (with VT100 terminal emulation software) and a straight through serial cable with a DB-9
(male) connector on one end and the appropriate interface for your terminal (or PC) on the other.
Configure the Gateway IP addresses and subnet mask by following
these steps. If you are not sure what IP address to assign, please
contact your network administrator.
1. Connect the DB-9 (male) connector of your serial cable to the console port on the rear
panel of the unit.
1. Enter enable to activate the Enable command security mode.
2. When prompted, enter the enable password (if configured).
3. Enter config terminal to activate the Global configuration mode.
2. Connect the loose end of the serial cable to the VT100 terminal or PC (with terminal
emulation software).
4. Enter bre lan-gw 10.26.12.12 wan-gw 100.26.12.12 mask
255.255.255.0* to assign LAN and WAN Gateway IP addresses
and subnet mask.
3. Open a VT100 terminal session to the Total Access 234 using the following settings:
9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the
ADTRAN Command Line Interface (CLI).
*Note: Underlined text represents example entries only. Modify
them to match your configuration.
SPECIFICATIONS
5. Enter exit to return to the Enable configuration mode.
DC Input Power
Diagnostics & Test
EMC Emissions
12 VDC nominal (8.5 VDC min, 18 VDC max); ITU-T standards: G.991.2
Self-diagnosis; local loopback; remote loopback
6. Enter copy running-config startup-config to save the running
configuration to the unit’s non-volatile memory (NVRAM).
EN55022:1998 Class B; FCC Part 15 Class B
FEATURES
EMC Immunity, Power
Fault, and Lightning
EN55024:1998; EN61000-3-2; EN61000-3-3; Telstra 1563; K.21 (2004)
Enhanced
•
•
•
•
•
•
•
•
One integrated EIA-232 configuration port (DCE)
One integrated 10/100BaseT Ethernet port
2-Wire/4-Wire SHDSL interface
Electrical Safety
EN60950; AS/NZS 60950; UL60950 3rd ed.;
CSA C22.2 No. 60950 3rd ed.; IEC 60950 CB Scheme
WAN Protocol: ATM
Telecom
S043.2; G.991.2
Command Line Interface (CLI)
Operating Temp: 0oC to 50oC; Storage Temp: -20oC to 70oC
Environmental
Management - EOC/CLI using Virtual Terminal
Front panel LEDs
*Note: No stacking should be done at 50oC. Up to three units can be stacked at room temperature.
Humidity: 95 percent noncondensing
Wall mounting available with additional parts
Dimensions
Connectors
9.3 inches W x 2.1 inches H x 6.1 inches D
SHDSL Port: RJ-45; 135 ohms; TNV-3 rated
10/100BaseT Ethernet: RJ-45
Table standoff cannot be used with this unit.
Console Port: DB-9 female
Power Input: Kycon KPJ-3S snap & lock or equivalent
Quick Start Guide, 61200708L1-13B, January 2005
Technical Support 1-888-4ADTRAN or +1-256-963-8716
Copyright © 2005 ADTRAN, All Rights Reserved
|