Special
Order
Products
TB-nM/D
Master Station with Selective Door Release
TB-10M/D 10-Call Master
TB-20M/D 20-Call Master
- SUPPLEMENT TO TB-M INSTRUCTIONS -
The TB-M/D Intercom and Selective Door Control System is designed for communication between a central master
station and remote door stations. The TB-M/D adds door release to the standard TB-M system. All information
regarding installation other than the external control functions is included in the TB-M instructions. In addition to
communication to remote locations, the Master Station can selectively release the corresponding door strike or
maglock.
WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
TB-10M/D
TB-AD1
For Door #10
IE/IF Door
Station
TB-AD1
For Door #9
1
2
3
~
9
1
2
IE/IF Door
Station
1
2
1
2
1
2
10
E
N
T
R
+
-
N
T
R
+
-
T
R
12+
12-
M
C
PS-18YC/A
Relays are activated
when the door
release button is
being pressed while a
station button is
selected.
AC/
DC
Input
Momentary Closure for Station #1
Momentary Closure for Station #9
Momentary Closure for Station #10
+
-
RY-PA
#1
1 ~
9
BLK
YEL
RY-PA
#9
BLK
YEL
BLK
10
RY-PA
#10
YEL
To activate door
release, press
button located by
TRANSFER button.
L
Common for each closure
To convert RY-PA to N/C (normally
closed) contact: Move one yellow wire
from "NO" to "NC". (Internal
External
Terminal Block
x
x
modification, soldering required.)
AC Power
for Door
Releases
Individual Components for System:
TB-M/D TERMINAL DEFINITIONS:
TB-nM/D
RY-PA
PS-18YC/A
PS-18C
Master station with selective contact output capability (10, 20)
Relay for selective output (1 per station requiring external contact)
18V DC, 1.2A Power Supply (For Audio Systems)
18V DC, 2A Power Supply (For Audio/Video Systems)
1 Audio Door Adaptor
+
-
1~10
E
M,C
T
Power input (18V DC or 16V AC)
Negative
Station number
Common communication
Master-to-Master communication
Transmit to door station
Receive from door station
Output to call extension speaker
TB-AD1
TB-AD10
TB-ADM10
IMPORTANT:
10 Audio Door Adaptor
10 Video Door Adaptor
R
S, S
1. RY-PA must be used for each selective contact to
isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on the
external terminal block.
SEPARATE TERMINAL BLOCK:
1~10 (20) Selective negative for each channel
L
Common Positive output for selective closure
Pg. 1
|