Aiphone Intercom System C 123LW User Manual

90102  
0610  
C-123LW Supplemental Instructions  
Dual Master ChimeCom System  
- REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD  
INSTALLATION INFORMATION -  
The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two  
inside locations. This supplemental instruction manual addresses many of the additional functions and modications  
for the Chime Com system, including installation and troubleshooting information.  
C-123L/A Set  
MASTER STATION:  
C-ML/A:  
Master station with door release button (Normally Open)  
COMPATIBLE DOOR STATIONS: (Weather resistant, made for outdoor use)  
C-D  
Surface mount, included in C-123L/A and C-123LW kit  
LE-D  
Surface mount, plastic door station (replacement for C-D)  
Flush mount in 2-gang box, stainless steel cover  
Vandal resistant, 1-gang ush mount, stainless steel  
Vandal resistant, 2-gang ush mount, stainless steel  
Vandal resistant, 2-gang ush mount, stainless steel, red mushroom button  
Vandal resistant, 3-gang ush mount, white powder-coat nish  
LE-DA  
LE-SS-1G  
LE-SS  
LE-SSR  
LS-NVP/C  
OPTIONAL COMPONENTS & ACCESSORIES:  
RY-AC/A  
DAK-2S  
External signaling relay (Requires 12VDC power supply)  
LE-SS-1G  
LE-SS  
LE-DA  
Dual master adaptor kit (2component modules)  
(1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)  
Surface mount box for LE-SS-1G  
Surface mount box for LE-SS, LE-SSR, LE-DA  
Surface mount box for LS-NVP/C  
Door strike (for interior wood frame doors only)  
AC 12V Transformer (used for door strike)  
6V DC power supply (1 per C-ML/A master)  
2 conductor, 22AWG, Shielded wire for up to 245’, (500’ and 1000’ boxes)  
2 conductor, 18AWG, Shielded wire for up to 590’, (1000’ box)  
Install two separate runs of this cable, one for the intercom and one for  
the door release.  
SBX-1G  
SBX-2G  
SBX-NVP  
EL-12S  
PT-1210N  
SKK-620B  
822202  
LS-NVP/C  
821802  
DAK-2S  
(2 component modules per kit)  
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.  
C-123LW Set contains:  
2 C-ML/A, 1 C-D, 1 DAK-2S  
C-D  
C-ML/A  
Power source and Door Strike not included.  
2 cond. shielded for intercom  
SKK-620B  
IMPORTANT: Connect wires  
before applying power.  
(or 4 “C” batteries installed in  
the master). Do not use both  
power sources. Ground wire  
must be tied to earth ground  
when using the SKK-620B.  
Power  
Source  
for Strike  
Separate 2 conductor for door release  
EL-12S, not included with the C-123L/A or C-123LW set.  
C-123LW Supplement  
Pg. 1  
 
WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC Relay  
Component  
Module*  
C-D  
C-ML/A  
IMPORTANT: Connect wires  
before applying power.  
1
1
Output of RY-AC (Yellow  
wires) provide a momentary  
dry contact closure while  
the call button on the door  
station is being pressed.  
E
E
12V DC power  
supply  
White  
BELL  
SKK-620B  
NOTE: Negative of  
power supplies must be  
tied together.  
Red  
+
-
+
-
RY-AC  
Black  
Power source  
for bell  
Normally Open Dry  
Contact to door  
strike and power  
L
L
Component Module*  
If a DAK-2S is not available, install components as shown below.  
Capacitor: 25V, 15-33ufd Non-polarized  
Diode: 1N4148  
To 1 of C-D and  
WHITE wire of RY-AC  
To 1 of C-ML/A  
MODIFICATION INSTRUCTIONS:  
C-ML/A with Door Release contact Modied to Normally Closed (for Magnetic Lock)  
C-ML/A Rear View with PC board removed.  
Magnetic locks require Normally  
Closed contacts, keeping power  
applied to the magnet to keep the door  
locked, and breaking power to release  
the door. These instructions explain  
how to change the contact in the  
C-ML/A to Normally Closed.  
1. Remove back chassis of C-ML/A  
and move the PC-754 board aside.  
Black door release switch will be  
visible.  
2. On the switch, move* the wire from  
the NO contact (middle position) to  
the NC contact (top position).  
*Desoldering and resoldering is  
required.  
3. This modication will change the  
door release button’s function to  
Normally Closed, to be used with  
magnetic lock device.  
-
+
Door release  
switch  
NC  
NO  
COM  
4. Switch contact rating is 1A at 50V  
AC.  
C-123LW Supplement  
Pg. 3  
 
INSTALLATION TIPS:  
1. Use shielded wire for the communication path, and ground one end of the shield to an earth ground.  
2. Run intercom wire at least 20” away from AC wiring, uorescent lights or dimmer switches.  
3. Keep intercom cable away from alarm, data, phone, video cables, and any other potential source of  
interference.  
4. Door release wires must be in a separately jacketed cable from the intercom wires. Use two separate  
cables; one for audio and one for door release.  
5. When installing a second master station, wire must be run from the rst master station, not from the  
door station. See diagram on page 2.  
6. Do not install the master station near light switches, dimmer switches, or other devices that may cause  
interference with the intercom system.  
7. Do not install the master station on the opposite wall from the door station. If the units are too close,  
acoustical feedback may result.  
TROUBLESHOOTING GUIDE:  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
When door calls in, it shorts the #1 terminal to the E terminal.  
If the DAK-2S is installed backwards the chime from the  
door call-in will not be heard. Install the DAK-2S component  
module with the bare wire under the 1 terminal, and the door  
station 1 wired to the colored wired end of the DAK-2S.  
No call in from door to master, but  
communication works ne.  
Reversed DAK-2S component module.  
When the talk button is pressed, the other  
master rings.  
Missing or reversed DAK-2S  
component module.  
Install the DAK-2S component module as described above  
and shown on the dual master instructions.  
If both C-ML/A’s share the same power supply, a ground loop  
feedback will occur when the talk button is pushed. Install a  
separate power source for each master.  
When the talk buton is pressed, feedback is  
heard at both masters.  
Common power supply.  
Terminals 1 and - crossed  
+/- are on left column, E/1 are on right column. If swapped,  
unit will appear dead. Verify that 1 from the door station is  
connected to 1, and negative of power supply is connected to -.  
Unit appears dead; No functionality  
Take batteries out of the master station. Both power sources  
cannot be used simultaneously.  
Power supply and batteries both  
installed.  
System squeals and batteries get hot  
Chime tone sounds weak, low frequency  
If batteries are installed, replace them. If using a power  
supply, check for 6VDC. If low, install a new SKK-620.  
Weak batteries or low voltage.  
Incorrect cable being used.  
If the resistance of the wire is too great, usually from  
exceeding distance limitations, the master may not time out as  
designed. Refer to wire specications in the instructions.  
Master stays on; does not time out.  
Voice volume is too loud or too soft.  
Remove front cover of the C-ML/A and locate volume  
potentiometer through hole at bottom of unit. Use a small  
screwdriver to adjust the volume, clockwise to increase.  
Volume control not adjusted properly.  
Standard volume level.  
There is not a separate call tone volume adjustment on the  
C-ML/A so the volume level cannot be altered. Surface mount  
component level modication would be required, which is not  
paractical  
Chime tone volume is too loud.  
Make sure the negative from the 12VDC supply for the RY-AC  
is connected to the negative of the C-ML/A master. Make sure  
the WHITE wire of the RY-AC is connected to the DAK-2S  
component module to terminal 1, not negative terminal.  
RY-AC external signaling relay not working.  
Missing or wrong connection.  
Aiphone Communcation Systems  
1700 130th AVE N.E.  
Bellevue, WA 98005  
(425) 455-0510  
C-123LW Supplement  
Pg. 4  
Toll Free Technical Support:  
1-800-692-0200  
#90102  
0610JD  
FAX (425) 455-0071  
 

2nd Ave Coffeemaker BF 40 User Manual
Accusplit Heart Rate Monitor S3MAGXLBK User Manual
Addonics Technologies Network Card AD2SAHDCF User Manual
Agilent Technologies Noise Reduction Machine E5500 B series User Manual
Allied Telesis Network Card GE8 User Manual
Altec Lansing Speaker IM5 User Manual
Alto Shaam Refrigerator 1000 mr2 User Manual
American Standard Plumbing Product Bathroom Faucet User Manual
Asus Cell Phone M530w User Manual
Atlona Home Theater Server AT 80140HD User Manual