R
E
I
F
I
D
I
M
U
H
E
D
MDF-50AE
MDF-70AE
MDF1-30AE
Before operating this product, please read the instructions
carefully and save this manual for future use.
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The
seriousness is classified by the following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
!
!
Meanings of symbols used in this manual are as shown below.
Never do this.
!
Always do this.
WARNING
!
!
Do not exceed the rating
of the power outlet or
connection device.
Do not operate or stop the
unit by switching on or off
the power.
Do not damage or use an
unspecified power cord.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
It may cause electric shock or fire
due to heat generation.
It may cause electric shock or fire.
!
Do not modify power cord
length or share the outlet
with other appliances
Do not insert or pull out
plug with wet hands.
Do not place the unit near
a heat source.
It may cause electric shock or
fire due to heat generation.
It may cause electric shock.
Plastic parts may melt and cause
a fire.
!
!
Disconnect the power if
strange sounds, smell, or
smoke comes from it.
You should never try to take
apart or repair the unit by
yourself.
Before cleaning, turn off
the power and unplug the
unit.
It may cause fire and electric
shock.
It may cause failure of machine
or electric shock.
It may cause electrical shock or
injury.
Do not use the machine near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
Do not drink or use the
water drained from air
conditioner.
Do not open the unit
during operation.
It contains contaminants and
could make you sick.
It may cause electric shock.
It may cause an explosion or fire.
CAUTION
!
!
When using in closets or
other small spaces, be
sure to keep doors open.
Do not put in places where
water may splash onto the
unit.
Place the unit on a
level, sturdy section of
the floor.
If the unit falls over, it may
cause water to spill and
damage belongings, or
cause electrical shock or
fire.
Lack of ventilation can cause
overheating and fire.
Water may enter the unit and
degrade the insulation. It may
cause an electric shock or fire.
2
SAFETY PRECAUTIONS
!
CAUTION
!
Care should be taken when
using the unit in a room with
the following persons:
Do not cover the intake or
exhaust openings with
cloths or towels.
Do not use in areas
where chemicals are
handled.
This will cause the unit
deterioration due to
chemicals and solvents
dissolved in the air.
Infants, children, elderly people,
and people not senstive to
humidity.
A lack of air flow can lead
to overheating and fire.
!
When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.
Do not climb up on
or sit on the unit.
Do not place heavy object on the
power cord and take care so that
the cord is not compressed.
You may be injured if you
fall or if the unit falls over.
Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.
There is danger of fire or
electric shock.
!
If water enters the unit, turn
the unit off and disconnect the
power , contact a qualified
service technician.
!
Always insert the filters
securely. Clean filter
once every two weeks.
Do not place flower
vases or other water
container on top of
the unit.
Operation without filters
may cause failure.
It may cause failure of
appliance or accident.
Water may spill inside the
unit, causing insulation
failure and electrical
shock or fire.
Electrical Information
The manufactures nameplate is located on the rear panel of
the unit and contains electrical and other technical data
specific to this unit.
Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The
power cord is equipped with a three-prong grounding plug
for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or
circuit breaker, have a qualified electrician install the proper
receptacle.
This unit is grounded through the
power cord plug when plugged
into a matching wall outlet.
Ensure the receptacle is accessible after the unit installation.
Do not use extension cords or an adapter plugs with this
unit. However, if it is necessary to use an extension cord, use
an approved air conditioner extension cord only (available
at most local hardware stores).
To avoid the possibility of personal injury, always disconnect
the power supply to the unit, before installing and/or servicing.
3
CONTROL PADS ON THE DEHUMIDIFIER
Continuous
operation on
indicator light
Bucket full
indicator light
High fan
indicator
light
Power on
indicator light
Normal fan
indicator light
5
Power
Normal
Continuous
Turbo
Full
C
Humidity%
1
2
4
3
Fig.1
Control pads
4
Fan speed Pads
1
POWER Pad
Control the fan speed. Press to select either High or Normal
fan speed. Set the fan control to High for maximum moisture
removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Normal.
Press to turn the dehumidifier on and off.
2
Continue Pad
Select for the dehumidifier to operate
continuously for maximum dehumidification
until the bucket is full. The Humdity set
control pads cannot be used when
Continuous operation is on.
5
Display
Shows the set % humidity level while setting, then shows
the actual(+5% accuracy) room % humidity level.
Error Codes:
E1- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
E2- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P1- Unit is defrosting-- Allow the unit time to automatically
defrost. The error will clear after the unit self defrosts.
P2- Bucket is full-- Empty the bucket and replace in
the right position.
3
Humidity Set Control Pads
The humidity level can be set within a
range of 35%RH(Relative Humidity) to
80%RH(Relative Humidity) in 5%
increments.
For drier air, press the
pad and set
to a lower percent value(%).
For damper air, press the
pad and
set a higher percent value(%).
Other features
Bucket Full Light
Auto Defrost
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
Auto Shut Off
Power Outage
The water level control switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position. When the setting humidity
In the case of a power outage or interruption, the unit will
automatically re-start, in the settings last used, after the
power is restored.
is reached, the unit will be shut off automatically.
4
IDENTIFICATION OF PARTS
Identification of parts
Front
1
2
Handel
Air outlet
grille
Air outlet
grille
Control panel
Control panel
Air intake
grille
Handel
Air intake
grille
Water bucket
Water bucket
Water level
window
Water level
window
Fig.2
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape
of the unit you purchased may be slightly different, but the operations and functions
are the same.
Rear
Air Outlet grille
Air filter
Drain hose outlet
(see page 8)
Power cord hook or Band
(depending on models)
(Used only when storing
the unit.)
Caster
Power Plug
Power Cord
Fig.3
5
OPERATING THE UNIT
Positioning the unit
A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed
storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
Do not use outdoors.
40cm or
This dehumidifer is intended ofr indoor residential
more
applications only. This dehumidifier should not be used
for commercial or industrial applications.
Air outlet grille
Place the dehumidifier on a smooth, level floor strong
enough to support the unit with a full bucket of water.
Allow at least 20cm of air space on all sides of the unit
for good air circulation.
Air intake
grille
Place the unit in an area where the temperature will not
falll delow 5 C(41 F). The coils can become covered with
frost at temperatures below 5 C(41 F), which may reduce
performance.
20cm or more
20cm or more
20cm or more
Place the unit away from the clothes dryer, heater or radiator.
Use the unit to prevent moisture damage anywhere books
or valuables are stored.
20cm or more
Fig.4
Casters(At four points on the bottom of unit)
Casters can only move laterally.
Use the dehumidifier in a basement to help prevent
moisture damage.
Do not force casters to move over carpet,
nor move the unit with water in the bucket.
(The unit may tip over and spill water.)
The dehumidifier must be operated in an enclosed
area to be most effective.
Close all doors, windows and other outside openings
to the room.
When using the unit
When first using the dehumidifier, operate the unit continuously 24 hours.
This unit is designed to operate with a working environment between 5 C and 35 C.
If the unit has been switched off and needs to be switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other electrical appliances.
Select a suitable location, making sure you have easy access to an electrical outlet.
Plug the unit into a 115V~ 60Hz electrical socket-outlet with earth connection.
Make sure the Water bucket is correctly fitted otherwise the unit will not operate properly.
6
CARE AND MAINTENANCE
Removing the collected water
1. Pull out the bucket a little.
There are two ways to remove collected water.
1. Use the bucket
When the bucket is full, the unit will automatically stop
running, and the Full indicator light will flash.
Slowly pull out the bucket. Grip the left and right handles
securely, and carefully pull out straight so water does
not spill. Do not put the tank on the floor because the
bottom of the bucket is uneven. Otherwise the bucket
will fall and cause the water to spill.
Throw away the water and replace the bucket. The
bucket must be in place and securely seated for the
dehumidifier to operate.
Fig.5
2. Hold both sides of the bucket
with even strength, and pull it
out from the unit.
The machine will re-start when the bucket is restored
in its correct position.
NOTES:
When you remove the bucket, do not touch any parts
inside of the unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
Fig.6
2. Continuous draining
3. Pour the water out.
Water can be automatically emptied into a floor
drain by attaching the unit with a water hose
(not included).
Remove the water bucket from the front of the unit, you will
find a section of hose located above the bucket.
Remove the rubber plug from the back of the unit and store
it in a safe location(see Fig.8).
Fig.7
Insert the water hose through the hole in the back of the unit
and securely press it onto the connector on the front of the
unit(see Fig.9). Then lead the water hose to the floor drain or
a suitable drainage facility.
Remove the
rubber plug
Replace the bucket in the unit. The bucket must be in place and
securely seated.
Push the hose
into the drain
hole
Fig.8
NOTE: When the continuous drain feature is not being
used, remove the drain hose from the connector and
attach the back drain hole with the rubber plug shown
in Fig.1.
Drain hose
Connector
Fig.9
7
CARE AND MAINTENANCE
Care and cleaning of the dehumidifier
Turn the dehumidifier off and remove the plug
from the wall outlet before cleaning.
1. Clean the Grille and Case
Household
Drain
Use water and a mild detergent. Do not use bleach
or abrasives.
Cleaner
No
Do not splash water directly onto the main unit. Doing
so may cause an electrical shock, cause the insulation
to deteriorate, or cause the unit to rust.
The air intake and outlet grilles get soiled easily, so use
a vacuum attachment or brush to clean.
2. Clean the bucket
Every few weeks, clean the bucket to prevent growth of mold,
mildew and bacteria. Partially fill the bucket with clean water
and add a little mild detergent. Swish it around in the bucket,
empty and rinse.
NOTE: Do not use a dishwasher to clean the bucket.
After clean, the bucket must be in place and securely
seated for the dehumidifier to operate.
3. Clean the air filter
The air filter behind the front grille should be
checked and cleaned at least every 30 days
or more often if necessary.
NOTE: DO NOT RINSE OR PUT THE FILTER
IN AN AUTOMATIC DISHWASHER.
Fig. A
Fig. B
To remove:
Grip the tab on the filter and pull it out as shown
in Fig.A.
Clean the filter with warm, soapy water. Rinse and
let the filter dry before replacing it. Do not clean the
filter in a dishwasher.
To attach:
Insert the air filter into the unit from the side and push
it in. See Fig.C
Fig. C
Power cord
CAUTION:
DO NOT operate the dehumidifier without a filter
because dirt and lint will clog it and reduce
performance.
Band
4. When not using the unit for long time periods
After turning off the unit, wait one day before
emptying the tank.
Clean the main unit, bucket and air filter.
Wrap the cord and bundle it with the band or twist the excess
cord onto the power cord hook(depending on models).
Cover the unit with a plastic bag.
Store the unit upright in a dry, well-ventilated place.
8
TROUBLESHOOTING TIPS
Before calling for service, review the chart below first yourself.
Problem
What to check
,
Make sure the dehumidifier s plug is pushed completely into the
outlet.
Check the house fuse/circuit breaker box.
Dehumidifier has reached its preset level or bucket is full.
Tank is not in the proper position.
Unit does not start
Did not allow enough time to remove the moisture.
Make sure there are no curtains, blinds or furniture blocking the
front or back of the dehumidifier.
Dehumidifier does not
dry the air as it should
The humidity control may not be set low enough.
Check that all doors, windows and other openings are securely
closed.
Room temperature is too low, below 5 C(41 F).
There is a kerosene heater or something giving off water vapor
in the room.
The air filter is clogged.
The unit is tilted instead of upright as it should be.
The floor surface is not level.
The unit makes a loud
noise when operating
Frost appears on the
coils
This is normal. The dehumidifier has Auto defrost feature.
Hose to connector or hose connection may be loose.
Intend to use the bucket to collect water, but the back
drain plug is removed.
Water on floor
These are error codes. See the CONTROL PADS ON THE
DEHUMIDIFIER section.
E1, E2, P1 or P2 appear
in the display
9
220266A044
|