Alpha ToolComHK Limited Boiler HE CB33 User Manual

User's  
Instructions  
AlphaHECB25/33andHESY25  
Wall Mounted, Fan Assisted, Room Sealed, Gas Fired,  
High Efficiency Condensing Boiler Range  
For Technical help or for Service call ...  
ALPHA HELPLINE  
Tel: 0870 3001964  
Nepicar House, London Road,  
Wrotham Heath, Sevenoaks,  
Kent TN15 7RS  
British Gas  
Service Listed  
Alpha HE CB25 G.C. No. 47 532 25  
Alpha HE CB33 G.C. No. 47 532 26  
Alpha HE SY25 G.C. No. 41 532 07  
For use with Natural Gas only  
Leave these instructions with the User  
 
3 BOILER CONTROLS  
1. CENTRAL HEATING THERMOSTAT  
This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum output from the  
radiators the thermostat should be turned fully clockwise i.e. maximum output. If lower heating temperatures are required, turn the  
thermostat anti-clockwise.  
2. DOMESTIC HOT WATER THERMOSTAT - HE CB25/33 only  
This thermostat controls the temperature of the domestic hot water leaving the boiler. For maximum hot water temperatures the  
thermostat should be left at maximum i.e. fully clockwise. If lower temperatures are required, turn the thermostat anti-clockwise.  
3. SELECTOR SWITCH  
This control allows the boiler to provide central heating and hot water or hot water only.  
Note: The internal clock and frost thermostat will not operate when the switch is in the vertical position, i.e. 'Off' position (0).  
4. PRESSURE GAUGE  
This indicates the central heating system pressure. It should always be within the green band when cold, increasing slightly  
when hot.  
If the pressure falls below the green band, i.e. lower red area, refer to the label on the inside of the hinged control panel cover  
for guidance on re-pressurising the system. Or contact your Installer to have the system checked and pressurised.  
Note: The bleeding of radiators will cause the pressure to fall and the system will require re-pressurising after doing so.  
5. INDICATOR NEONS  
When neon A (red) and neon B (yellow) are illuminated, the following conditions apply:-  
Neon  
B
B
B
Flashing very slowly (every 5 seconds) - Electricity supply to the boiler is on.  
Illuminated continuously - Burner is alight.  
Flashing on and off - Temperature sensor fault, contact your Service Engineer.  
A
A
Flashing on and off - Overheat or flue thermostat has operated. Rotate selector switch to the reset position (3) to reset. If this  
continues to happen, contact your Service Engineer.  
Illuminated continuously - Burner has failed to light. Rotate selector switch to the reset position (3) and the ignition  
sequence will restart after a delay of about 30 seconds.  
A and B Flashing on and off at the same time - Blocked flue or fan fault, contact your Service Engineer.  
A and B Flashing on and off alternately - System pressure is very low and re-pressurisation is required.  
A Illuminated continuously and B flashing - Pump fault or restricted flow.  
6. OVERHEAT THERMOSTAT  
This thermostat automatically switches the boiler off in the unlikely event of the boiler overheating. When the thermostat operates,  
the red neon (A) flashes on and off. Rotate the selector switch to the reset position (3) and the boiler will relight.  
If this continually happens, contact your Service Engineer.  
7. PRESSURE RELIEF VALVE  
If the central heating system overheats and steam or water is discharged from the pipe connected to this valve, turn the boiler off  
and contact your Service Engineer. Your Installer should have shown you where this pipe terminates, usually outside your dwelling.  
8. FROST THERMOSTAT  
The boiler has a built-in frost thermostat, which automatically operates the boiler if the water temperature falls below 8°C,  
providing the electrical supply is on and the selector switch is set to position (1) or position (2).  
Alpha HE CB/SY  
3
 
4 LIGHTING INSTRUCTIONS  
Refer to Fig. 1a or 1b for boiler controls.  
1. Ensure the following:-  
a. Electrical supply to the boiler is off.  
b. All heating controls and thermostats are set to OFF or minimum position.  
c. All isolation valves at the bottom of the boiler are in the open position (slot on the spindle in line with the valves i.e. ).  
d. The gas and water supplies are on at the mains.  
e. The heating system pressure is within the green band as shown by the pressure gauge.  
2. Switch on the electrical supply to the boiler.  
3. Set any room thermostats to maximum and ensure that any clock is in an 'on' position.  
4. HE CB25/33 only - Set the selector switch to  
(hot water only).  
5. HE CB25/33 only - Turn the hot water thermostat fully clockwise. Open a hot water tap, the main burner will light and the  
boiler will provide hot water. Close the tap and the burner will go out.  
6. Set the selector switch to position (2) and turn the heating thermostat fully clockwise, refer to Section 3.1. The main burner  
will light and the boiler will provide central heating.  
7. Set the boiler thermostats, clock, external controls i.e. room thermostat to your chosen settings and the boiler is ready to operate.  
To turn the central heating off i.e. in Summer:- Set the selector switch to position (1).  
To turn the boiler off for short periods:- Set the selector switch to position (1).  
Note: In this position the pump will automatically operate for 5 minutes in every 24 hours. If the water temperature falls below  
8°C the built-in frost thermostat will operate the boiler automatically until the temperature of the water in the heating system has  
been raised.  
To turn the boiler off for longer periods:- Switch off the electrical supply to the boiler. If required, all supplies i.e. gas, water  
and electricity may be turned off at the mains. If there is any possibility of the boiler being left during frost conditions, then the  
boiler and system should be drained and a label attached to the boiler drawing attention that the system has been drained. If  
this is required, contact your Service Engineer.  
5 BOILER OPERATION  
The operating sequence of the boiler is controlled by the selector switch on the control panel. When the HE CB25/33 selector switch  
is set to  
(hot water only) the boiler will only operate to provide domestic hot water, ideal for Summer use when central heating  
is not required.  
With the selector switch set to position (2) the boiler will operate to provide central heating and for the HE CB25/33 hot water as  
well.  
HE CB25/33 only - If the boiler is operating to provide central heating and a hot water tap is opened, the boiler will automatically  
switch over to provide hot water. Such an interruption in the central heating should not generally be noticed by any reduction in room  
temperature.  
Note: If a clock is fitted to the HE CB25/33 boiler, it will only control the operating times of the central heating. Hot water will  
always be available when a tap is opened. If a two channel clock is fitted to the HE SY25 boiler it will control the operating times  
of the central heating and hot water.  
When the selector is set to position (2), it will respond to a demand for heat in the following sequence:-  
a. The pump will start, the fan will operate at full speed and the main burner will light.  
b. The output of the burner is automatically controlled to suit the system demand.  
c. When the temperature of the system water in the boiler reaches that set by the thermostat or the room thermostat is  
satisfied, the main burner is turned off and the fan stops after 20 seconds. The pump will continue to run to remove any  
residual heat from the boiler.  
d. HE CB25/33 only - When a hot tap is opened, the boiler automatically senses a flow of water. The pump will start, the fan  
will operate at full speed and the main burner will light.  
e. HE CB25/33 only - The boiler will continue to supply hot water at the temperature set by the thermostat until the tap is closed.  
6 HOT WATER USE - HE CB25/33 only  
The supply of hot water is almost instantaneous at the boiler, but the time taken to reach a tap and the temperature at which it leaves  
the tap will depend on the rate at which the water is drawn off and the length of the pipe between the tap and the boiler.  
Fully opening a hot tap may not always provide the maximum temperature as the flow rate may be too high, try closing it slightly  
until the maximum temperature is achieved.  
Depending on your mains water pressure, it may not be possible to operate several hot taps at the same time.  
Alpha HE CB/SY  
4
 
7 USING A SHOWER - HE CB25/33 only  
Thermostatic or pressure equalising type - When using these types of shower set the boiler domestic hot water thermostat  
to maximum. The shower should then maintain a relatively constant temperature.  
Manual bath mixer type shower - When using this type of shower set the boiler domestic hot water thermostat to setting 7,  
This should avoid excessive temperatures at the shower.  
Note: If you get unacceptable temperature variations with this type of shower, then a thermostatic or pressure equalising type  
should be used.  
8 IMPORTANT NOTES  
1. BOILER LOCATION  
Always ensure the following clearances are available around the casing of the boiler:-  
Top: 220 mm, Bottom: 250 mm, Each side: 5 mm, Front: 450 mm  
Do not store any other articles in the cupboard containing the boiler and never place any clothing or combustible material on or near  
the boiler or flue pipe.  
2. FLUE TERMINAL  
The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and  
contact your Service Engineer.  
Note: The Alpha HE boilers are high efficiency boilers and when operating vapour will be emitted from the terminal. This is safe  
and quite normal.  
3. MAINS FAILURE  
In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal  
operation. Remember to reset the clock when the supply is restored.  
HE CB25/33 only - If the mains water supply fails, there will be no hot water from the taps. The boiler will continue to provide  
central heating.  
4. ADDITIONAL BATHROOM FITTINGS - HE CB25/33 only  
Any equipment such as mixing valves, showers, bidets etc. must be designed to operate at mains water pressure. Contact your  
plumbing merchant or installer for advice when considering purchasing such items.  
5. CLEANING  
Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners.  
6. SERVICING  
To maintain efficient and safe operation of your boiler, routine annual servicing is essential.  
For advice on servicing contact:- The Alpha Helpline: 0870 3001964  
7. GAS LEAK  
If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all  
naked flames. Contact your local Gas Region immediately.  
8. ELECTRICAL SUPPLY  
The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used.  
To connect a plug:-  
The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals  
in your plug. In this case proceed as follows:-  
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the  
earth symbol  
, or coloured green or green and yellow.  
The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.  
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.  
THE APPLIANCE MUST BE EARTHED.  
Alpha HE CB/SY  
5
 
9 GAS SAFETY REGULATIONS  
Current Gas Safety (Installation and Use) Regulations:-  
It is the law that all gas appliances are installed and serviced by a competent person, i.e. CORGI registered personnel. Failure  
to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance  
with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.  
The Benchmark Checklist must be fully completed by the installer on installation and commissioning of the boiler. The  
Benchmark Checklist is shown in Section 12, page 43, of the Installation and Servicing instructions. All CORGI registered  
installers carry a CORGI ID card and have a registration number. Both should be recorded in the Checklist. You can check your  
installer is CORGI registered by calling CORGI on 01256 372300.  
Alpha HE CB/SY  
6
 
10 FAULT FINDING FORTHE USER  
If you experience a problem of no heating or hot water, try to solve the problem by following the simple checks below before  
calling out a service engineer.  
Pull the controls panel cover forward and down to gain access to the controls.  
Alpha HE CB/SY  
7
 
Alpha Therm Limited.  
These instructions have been carefully prepared but we reserve the right to  
alter the specification at any time in the interest of product improvement.  
© Alpha Therm Limited 2005.  
NepicarHouse,LondonRoad,WrothamHeath,  
Sevenoaks, Kent TN15 7RS  
Tel: 0870 3001964  
Part No. 1.022793  
Manual compiled and designed by Publications 2000 - Tel: (01670) 356211  
06/05/D187  
 

3Com Digital Camera iCV 01a User Manual
Acu Rite Weather Radio 00305TG User Manual
ADTRAN Network Card NT1 ACE User Manual
Aiwa CD Player CX NHMT75 User Manual
Alcatel Lucent Switch 6850 24 User Manual
Alesis Home Theater Server 6FX User Manual
American Standard Hot Tub 2425118W User Manual
American Standard Indoor Furnishings 0495221 User Manual
Behringer Musical Instrument PMH1000 User Manual
Beko Double Oven DVG593 User Manual