Amcor Air Conditioner AMC 10KM 410 User Manual

AMC 7KM-410 10KM-410 12KM-410  
GB  
Portable air conditioner  
 
GB  
THANK YOU  
Thank you for choosing this innovative Amcor air conditioner. We suggest that you  
keep this manual in a safe place for future reference. It describes the many benefits  
and advanced features this unique product has to offer. Before you use your air  
conditioner you should carefully read these instructions to maximise this product’s  
performance.  
For over 50 years Amcor has specialised in complete indoor environmental control,  
manufacturing and marketing; dehumidifiers, portable air conditioners, coolers, air  
purifiers, ionisers and aroma therapy scent diffusers. These world class products  
incorporate the latest technological developments.  
SAFETY INSTRUCTIONS  
IMPORTANT!  
• The unit is designed for indoor operation.  
• Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet.  
• The installation must be in accordance with regulations of the country where the  
unit is used.  
If you are in any doubt about the electrical installation, have it checked and if  
necessary modified by a qualified electrician.  
• The air conditioner is safe. However, as with other electrical appliances, use it  
with care.  
• Keep out of the reach of children.  
• Do not clean the unit by spraying it or immersing it in water.  
• Do not insert any object into the openings of the unit.  
• Disconnect it from the mains before cleaning the unit or any of its components.  
• Never connect the unit to an electrical outlet using an extension cord. If an outlet  
is not available, one should be installed by a licensed electrician.  
WARNING  
• Never operate this appliance if it has a damaged cord or plug. Do not lead the  
cord over sharp edges.  
• A damaged supply cord should be replaced by the manufacturer, its service agent  
or a qualified person in order to avoid a hazard.  
• Any service other than regular cleaning or wick replacement should be performed  
by an authorized service representative. Failure to do so could result in a loss of  
warranty.  
3
 
GB  
Do not use your cooler under the following conditions:  
If the power cable  
wires are frayed  
or cut  
When small  
children may be  
left unattended  
On a slope or  
uneven surface  
Close to a heat  
source  
This products is  
not made for DIY  
repair  
If there is a risk of  
liquid falling on  
the unit  
Inside unit exposed  
to the weather  
outdoors  
In a humid  
environment  
If an extension  
lead may become  
overloaded  
Where the power  
cable may be  
damaged  
Where it may  
be damaged by  
chemicals  
Where there is a  
risk of interference  
by foreign objects  
ELECTRIC CONNECTION (see page 8 on how to wire a plug)  
For your safety please read the following information.  
Warning: This appliance must be earthed.  
This appliance operates from a 3 pin 13 amp plug. The voltage rating is 230 volts  
and should be protected by a 13 amp fuse either in the plug or distribution board.  
The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a  
13 amp fuse. Should the fuse require replacement, it must be replaced with a fuse  
rated at 13 amp and approved to BS1362.  
The plug contains a removable fuse cover that must be refitted when the fuse is  
replaced. In the event of the fuse cover being lost or damaged, the plug must not be  
used until a replacement cover has been obtained.  
If the moulded mains plug is unsuitable for the socket outlet in your home or is  
removed for any other reason, then the fuse should be removed and the cut off plug  
disposed of safely to prevent the hazard of electric shock.  
There is a danger of electric shock if the cut off plug is inserted into any 13 amp  
socket outlet.  
4
 
GB  
POSITIONING  
This unit is portable and can easily be moved from one room to another. In doing  
so keep this in mind:  
• The air conditioner must stand upright on an even surface.  
• Position not (near) bath, douche or other wet or damp area.  
• Keep for free air circulation at least 50 cm free from any obstacle or curtains.  
1
Installation  
16  
• Put the exhaust hose into the round side of the exhaust hose  
adapter (13) (fig. 1).  
13  
• Put the wall/window adapter (14) onto the exhaust hose  
(fig. 2).  
2
16  
• Connect the hose with the rectangular end to the air  
conditioner (fig. 4).  
14  
3a  
3b  
15  
4
5
6
Using the foam.  
Place the foam with the hole (11), if needed together with the foam extension (10),  
in the window and close this as far as possible to refrain the warm air from re-  
entering the room (fig. 5). Depending on how the window opens, horizontally  
(fig. 3a) or vertically (fig. 3b).  
Pass the hose through the opening in the foam (11).  
Permanent hole in glass or wall.  
Place the wall/window connector (14) in the hole with diameter 130 millimetre  
(fig. 6). Connect the hose with the rectangular end to the air conditioner (fig. 4).  
Use the cap (15) to close the opening when the air conditioner is not used.  
Important  
The flexible exhaust hose can be extended from 300 to 1500 mm for mounting.  
This length has been designed especially according to the specifications of the air  
conditioner. Do not use an extension or exchange for a different hose as that may  
lead to malfunctioning.  
The exhaust air must flow freely, any blockage can lead to overheating of the air  
conditioner. Take care to prevent any bow or bend in the exhaust hose.  
5
 
GB  
OPERATION  
1
2
3
4
3
2
1
ON/OFF and timer function  
Turn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on.  
Timer function  
Use control [1] to set a working time between 1 and 8 hours. The unit switches off  
when the set time has run down.  
Mode selection and speed setting  
Select with control [2] the required operating mode cooling or fan mode. The  
corresponding LED (2 or 3) will lit.  
Select the larger symbol position for high or low fan speed, or low or strong cooling.  
Thermostat setting  
Turn control [3] to maintain the temperature level in combination with cooling.  
Notices:  
• The compressor has been set so that it starts functioning three minutes after the  
(re)start of the air conditioner.  
• The cooling will switch off when the room temperature is lower than the set  
one. Ventilation will however continue to work on the set level. When the room  
temperature rises above the selected value, the cooling will work again.  
Air flow  
Turn the roller to control the air flow direction of the vertical  
louvres.  
Move the air vent directly to adjust the air flow direction of the  
horizontal louvres.  
6
 
GB  
EMPTYING THE INTERNAL WATER CONTAINER  
When the water container is full, the compressor and  
the ventilator stop functioning, LED [4] will lit.  
Switch off the unit and remove the plug from the  
mains.  
Rubber plug  
Water tray  
• Place the water tray flat on the floor under the drain.  
• Remove the drain knob.  
Drain control  
• Remove the rubber plug and fill the water tray then replace the plug to stop  
the water flow. Empty the tray and repeat this process until all water has been  
removed.  
• Replace the rubber plug and the drain knob, plug the unit in and switch on. The  
LED [4] should now be out.  
PERMANENT DRAINAGE  
Switch off the unit and remove the plug from the mains.  
• Remove the drain knob and the rubber plug.  
• Connect the correct water tube onto the water outlet.  
• Place the other end in a normal drain.  
• Make sure that the tube is free from twists and bends.  
The tube must incline over its entire length.  
Dehumidification  
If the unit will be used mainly as dehumidifier, do not connect  
the exhaust hose and let the warm air return in the room.  
Continuous drainage is then convenient and more efficient.  
7
 
GB  
CLEANING  
First of all switch off the unit and pull the plug.  
Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol,  
detergents or other cleansing solutions.  
Filter  
The single layer screen filter cleans the circulated air. The filter needs to be cleaned  
regularly with a vacuum cleaner to avoid blocking the air flow.  
• Push the two clips on the filter housing downward and pull the filter housing  
forward and out of the unit.  
• Remove the rear retainer from the housing by gently prising it from the retaining  
clips.  
• Insert the screen filter aligning the two cut outs with the clips on the top of the  
filter housing.  
• Reverse the procedure to re-fit the housing in the air conditioner.  
Notice! Never use the air conditioner without filter.  
STORAGE  
See the instructions "Emptying the water container" on page 7.  
• Drain the condensed water completely.  
• Clean (or replace) the filter.  
• Put the unit on a sunny day in fan mode for a couple of  
hours to ensure that the inside becomes completely dry.  
• Store the power cable as shown, protect the unit against  
Cable storage  
dust and store in a dry place not accessible for children.  
ELECTRIC CONNECTION  
Important: how to wire a 13 amp plug  
GREEN/YELLOW  
The wires in the mains lead on this appliance are  
Earth  
BROWN  
Live  
coloured in accordance with the following code:  
GREEN AND YELLOW – EARTH  
BLUE – NEUTRAL  
BROWN – LIVE  
As the colours may not correspond with the markings  
identifying the terminals in your plug proceed as  
follows:  
BLUE  
Neutral  
FUSE  
13 Amp  
The GREEN AND YELLOW wire must be connected to the  
terminal in the plug which is marked with the letter  
E or with the earth symbol or coloured green and  
yellow.  
Cord clamp  
The BLUE wire must be connected to the terminal marked N or coloured black.  
The BROWN wire must be connected to the terminal marked L or coloured red.  
8
 
GB  
TROUBLE SHOOTING  
Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in  
loss of warranty and can endanger the user.  
Problem  
Cause  
Solution  
The unit does  
not function  
Check the plug fuse. Check  
the mains outlet by connecting switch on  
another appliance  
Connect to a functioning outlet and  
Water container indicator is on Empty water container  
Room temperature outside  
operating temperature range  
The unit does  
not seem to  
perform  
In direct sunlight  
Windows or doors open, many  
people or heat source in room  
Close curtains  
Dirty filter  
Clean or replace filter  
Remove blockage  
Air inlet or air outlet blocked  
Room temperature lower than  
selected value  
Change temperature selection  
The unit is noisy Unit stands uneven  
Place on even surface (less vibrations  
)
The compressor Overheat protection probably  
Wait until room temperature lowers  
does not work  
activated  
TECHNICAL DATA  
Model  
AMC  
AMC  
AMC  
7KM-410  
10KM-410  
12KM-410  
BTU/h  
kW  
6500  
1.9  
8300  
2.4  
9600  
2.8  
Cooling capacity  
measured conform EN 14511  
Mains  
220–240 V / 50 Hz / 1 phase  
Power consumption  
Current  
Dehumidification  
Air delivery  
Recommended room size  
Refrigerant  
Compressor  
Fan speeds  
W
A
L/24h  
m3/h  
m2  
690  
3.0  
24  
300  
12  
830  
3.7  
28.8  
350  
18  
R410A  
rotary  
1030  
4.5  
36  
350  
24  
type  
2
Thermostat  
Timer  
°C  
h
18 – 32  
1 – 8  
Dimensions (W x H x D)  
Weight  
mm  
kg  
377 x 750 x 400  
30  
29  
32  
Subject to modifications without prior notice. Please refer to the rating label for greater precision.  
9
 
GB  
AMCOR GUARANTEE PROCEDURE  
Amcor products have a lower than industry norm failure rate, as we have strict quality  
control in our factory. However we are not 100% perfect and occasionally units can fail.  
When they do we have a simple returns procedure.  
All Amcor products are guaranteed for one-year from date of purchase, on a back to  
base principle. A copy of our guarantee page is attached.  
Consumers need to keep the till receipt as proof of purchase.  
The Amcor Help line number for the UK 020 8 560 4141 appears on the back of each  
unit and in the instruction manual.  
If a consumer believes the unit to be faulty the first course of action is to phone the  
Help line 0208 560 4141. A trained engineer will speak to them. Often we find that this  
eliminates 95% of no fault found, as the customer may not be using the product in the  
correct manner.  
If the engineer believes the unit may be faulty, Amcor will arrange collection by a carrier  
from the consumer. The product must be boxed and amply protected to avoid cosmetic  
damage in transit. If the consumer is unable to be present to allow for collection, the  
boxed unit can be collected from store. Of course Amcor pay the carriage charge.  
On reaching Amcor the unit is checked, repaired or replaced, re-boxed and returned  
again by carrier to an agreed return address. This process usually takes 5 – 7 working  
days.  
If the customer returns to store and claims the unit to be faulty we would ask that you  
carry out the same procedure as above, particularly with air conditioners, rather than  
simply exchange or refund. Again this eliminates the risk that the consumer is not using  
the product correctly. However goods returned faulty inside 28 days can be exchanged  
– usually faulty goods “dead on arrival” will be returned to store by the consumer within  
a few days.  
To exchange or refund DOA goods within 28 days stores must call Amcor on 020 8 560  
4141 (Monday – Friday 09.00 – 17.30 hrs.) for an authorisation number. If goods need  
to be exchanged over a week-end (or late evening) stores must contact Amcor on the  
next working day. Amcor will require store details, product details and date of purchase/  
return.  
Goods returned under 28 day agreement that are found to have significant wear & tear  
will not be credited; consequently stores must check purchase and return dates.  
Goods returned outside 28 days of purchase will not be authorised for return to Amcor.  
Instead we will collect / repair / return the unit under our normal guarantee procedure.  
Outside of the guarantee period Amcor are able to service or repair units for a  
reasonable cost. Consumers can get details of the cost from the Help line number.  
Consumables such as activated carbon filters can be bought directly from Amcor;  
payment can be by cheque or credit card.  
This guarantee is in addition to the customers’ statutory rights.  
10  
 
GB  
YOUR GUARANTEE  
DOMESTIC AIR CONDITIONERS  
If this product is found to be defective as a result of faulty materials or workmanship  
within one year from date of purchase, it will be repaired or replaced free of charge.  
This guarantee is subject to the following terms:  
Amcor Limited., must be notified of the fault  
Proof of purchase must be presented to Amcor’s nominated representative  
The warranty will be void if the product is modified, misused or repaired  
by an unauthorised person  
The guarantee does not cover accidental damage, misuse,  
or consumable items such as filters  
The guarantee after repair or replacement will not be extended  
beyond the original one-year period  
All replacement parts or units will be new or reconditioned  
Parts or units, which are replaced, become the property of Amcor Limited  
Amcor Limited disclaims any liability for incidental or consequential damages  
The warranty applies for the use of the product in UK.  
This GUARANTEE is in addition to your Statutory Rights.  
Creating Quality Environments  
AMCOR LIMITED • 9 Ryan Drive • West Cross Centre • Great West Road • Brentford  
Middlesex • TW8 9ER • UK  
For Customer Support Call: 020 8 560 4141  
Reminder:  
Waste electrical products must not be disposed of with household waste.  
This product should be taken to our local recycling centre for safe treatment.  
11  
 
Hong Kong  
Amcor Ltd  
Suite 2007, Tower 6, The Gateway,  
Harbour City, 9 Canton Road,  
Tsim Sha Tsui, Kowloon,  
Hong Kong  
Tel: +852 2997 6865  
Fax: +852 2997 6091  
United Kingdom  
Amcor Ltd  
9 Ryan Drive, West Cross Centre,  
Great West Road, Brentford,  
Middlesex, TW8 9ER,  
United Kingdom  
Tel: +44 20 8560 4141  
Fax: +44 20 8232 8814  
USA  
Amcor Inc.  
685A Gotham Parkway, Carlstadt,  
New Yersey 07072,  
United States of America  
Tel: +1 201 460 8100  
Fax: +1 201 460 9481  
The Netherlands  
Amcor B.V.  
Anton Philipsweg 9-11,  
1422 AL Uithoorn,  
The Netherlands  
Tel: +31 297 560 079  
Fax: +31 297 523 062  
Israel  
Amcor International Ltd  
1 Sapir St.,  
P.O. Box 12001  
Hertzeliya Pituach,  
Israel  
Tel: +972 9951 5351  
Fax: +972 9958 5650  
China  
Shan Xia Industrial Development Zone,  
Heng Li Town, Dongguan City,  
Guangdong Province, China  
Plant One - Amcor (China) Ltd  
Tel: +86 769 8372 1090  
Singapore  
Amcor Investments (Singapore) Pte Ltd  
545 Orchard Road,  
Fax: +86 769 8372 1790  
#13-02, Far East Shopping Centre,  
Singapore 238882  
Tel: +65 6297 9881  
Plant Two - Amcor Appliances Ltd  
Tel: +86 769 8372 1970  
Fax: +65 6297 8891  
Fax: +86 769 8372 1790  
 

Abocom Switch XP3242 User Manual
Accusplit Fitness Electronics EAGLE 1120 User Manual
ADTRAN Network Card 3010 NTU 8 User Manual
Agilent Technologies Video Gaming Accessories Agilent E3614A Serials KR83503035 User Manual
Aiwa CD Player NSX A10 User Manual
Amana Clothes Dryer LE4317W L2 User Manual
ATK Motorcycles Motorcycle 450 Dirt Track User Manual
Audiovox Automobile Electronics 128 8602 User Manual
Avery Label Maker ALS 230 User Manual
Beko Freezer BZ 77F User Manual