American Standard Plumbing Product M968628 REV13 User Manual |
Installation
Instructions
STUDIO
T590.50X
PRESSURE BALANCING
BATH AND SHOWER
TRIM KITS
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
M968628 REV.1.3
Recommended Tools
Phillips Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Teflon Tape
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
INLETS
1/2" NOM.
COPPER
SWEAT
INLETS
4-1/16"
1-5/8" TO 3-1/4"
FINISHED WALL
SHR. 1/2" NOM.
COPPER SWEAT
2-3/8"
2-3/8"
SWEAT
INLETS
1/2" NPT
2"
4-1/16"
4-1/16"
4-1/2"REF.
4-7/8" REF.
OPTIONAL TO
FINISHED FLOOR
USUALLY
TUB 1/2" NOM.
COPPER SWEAT
BETWEEN
8-1/2" REF.
80'' AND 86'
7-1/2" REF.
SWEAT
INLETS (STOPS)
5-7/8"
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
74" FOR
HEAD
CLEARANCE
INLETS
1/2" NOM.
COPPER
"SEE ILLUSTRATION"
8-1/4"
SWEAT
SHR
TUB
INLETS 1/2" NPT
6-11/16"
3-3/8"
18"
OPTIONAL
3-3/8"
4-3/4"
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
5-7/8"
INLETS
1/2" NPT
1/2" COPPER
1" MIN.
4"
TOP OF
TUB RIM
THREADED INLETS
3-3/8"
BOTTOM OF
TUB
THREADED INLETS (STOPS)
ADJUST HOT LIMIT STOP
3
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B"
to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
"RED RING"- HOT
LIMIT SAFETY STOP
1
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
"B"
PRY RED RING
"B"
FORWARD AND ROTATE
ADJUSTMENT WHEN
WATER IS TOO COLD
COUNTER-CLOCKWISE
ONE CLICK
TEMPERATURE
SETTING
NUMBERS
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
SERVICE
4
If faucet drips, operate handle several times from "off" to "on". Do
not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on"
hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4).
Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
5
4
1
CARTRIDGE
INLETS
3
2
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968628 REV.1.3
|