4. HOW TO USE YOUR XM1800S MOST EFFECTIVELY
Adjust the gain control in the microphone channel of your mixing console so that the peak LED lights
up only occasionally or never at all. The EQ controls in the microphone channel should be set to
mid-travel position to start with; low-cut filter and level attenuator should be turned off. Try to achieve
the desired sound by experimenting with the microphone position. Place the microphone as close to
the sound source as possible. The closer your mic gets to the sound source, the greater the bass
response will be. On the other hand, as you move the sound source further away from the microphone,
the bass response will gradually roll off (please see frequency response chart on next page).
Only when the desired basic sound has been achieved, should you start to use equalizers and
signal processors, if any at all. (Remember: less is often more!)
All microphones have characteristic polar patterns that determine how well signals from around the
area of the microphone are accepted or rejected.
The super cardioid pattern is used by the XM1800S. Thus, the XM1800S excels in environments
where a lot of undesired ambient noise exists. The XM1800S excellently reproduces those sound
signals originated directly in front of the microphone while rejecting or minimizing sound signals
originated in the area behind the microphone (please refer to the polar pattern on next page for
detailed information).
5. WARRANTY
+
or send us a request by e-mail ([email protected]), fax (+49 2154 9206 4199), or
telephone (+49 2154 9206 4166).
6. SPECIFICATIONS
Type:
Dynamic
Frequency response:
Polar pattern:
Impedance:
Sensitivity:
80 Hz - 15 kHz
Super cardioid
600 Ω
-52 dBV (0 dBV = 1 V/Pa), 2.5 mV/Pa
3-pin balanced XLR (male)
Connector:
Dimensions:
Head length
Main unit length
Total length
Weight:
57.5 mm
117.5 mm
175 mm
230 g
6. SPECIFICATIONS
3
DYNAMIC MICROPHONE XM1800S
POLAR DIAGRAM
FREQUENCY RESPONSE CHART
Fig. 6.1: Polar diagram and frequency response chart
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be
made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed or
illustrated.
The information contained in this sheet is subject to change without notice. No part of this sheet may be reproduced or transmitted
in any form or by any means, electronic or mechanical, including photocopying and recording of any kind, for any purpose,
without the express written permission of BEHRINGER Spezielle Studiotechnik GmbH.
BEHRINGER is a registered trademark. ALL RIGHTS RESERVED. © 2003 BEHRINGER Spezielle Studiotechnik GmbH.
BEHRINGER Spezielle Studiotechnik GmbH, Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Münchheide II, Germany
Tel. +49 2154 9206 0, Fax +49 2154 9206 4903
6. SPECIFICATIONS
4
|