Installation Guide
CB-TP17
Rough-In Box for 17" Wall/Flush Mount Touch Panels
Overview
Installing the 17" panel within a CB-TP17 Rough-In Box
Wall Mount panels (NXDs) are contained within a metallic outer housing (back
box). This back box is not removed when installing the NXD into a Rough-In
Box (CB-TP17). The back box is only removed to gain access for the
replacement of the Compact Flash component or upgrade to the VESA housing.
The Rough-In Box must be mounted prior to continuing this section. Verify that
all necessary cables have been threaded through the knockouts on the Rough-In
Box and the connections have been tested prior to installation of the 17" panel.
1.
Remove the magnetic faceplate/bezel (A in FIG. 1) from the main NXD unit
(B in FIG. 1) by gripping the faceplate and pulling with gentle outward force.
Verify the incoming RJ-45, Ethernet, and any other audio/video cables
have been properly threaded through the wiring knockouts on the left of the
Rough-In Box. Leave enough slack in the wiring to accommodate any
re-positioning of the panel.
The CB-TP17 Rough-In Box is an optional metallic box that is secured onto a
beam in a pre-wall setting (where no walls or present). Installation procedures
and configurations can vary.
2.
Specifications
3.
Connect all data and power wiring connectors to their corresponding
locations along the side of the (un-powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to a power
supply before plugging in the 2-pin power connector.
CB-TP17 (FG034-10) Specifications
Dimensions (HWD) • 13.55" x 17.07" x 3.49"
• 34.43 cm x 43.38 cm x 8.85 cm
•
•
The USB connectors can be from either a USB extension cable, or a
wireless USB RF transmitter.
Included
Rough-In Box Installation Kit (SA2001-02)
Accessories
• 4 Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)
• 4 Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)
Note: Don’t disconnect the connectors from the touch panel. The unit must be
installed with the attached connectors before being inserted into the CB.
Certifications
• cTUVus Listed
4.
Test the incoming wiring by connecting the panel connections to their
terminal locations and applying power. Verify the panel is receiving power
and functioning properly to prevent repetition of the installation.
Disconnect the terminal end of the power cable from the connected PSN
power supply.
WARNING: INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-
IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.
This gap allows the installation of the drywall/sheetrock after the CB-TP17 has
been mounted onto the beams. The stud notching and Rough-In Box installation
must be done prior to any wall installation.
5.
6.
7.
Carefully slide the main NXD unit (B in FIG. 1) into the Rough-In Box, so
the Mounting Tab lies flush against the Rough-In Box (C in FIG. 1).
Insert and secure four securing #8 flat-head Mounting Screws into their
corresponding holes located along the sides of the NXD. These #8 screws
are not included within the CB Installation Kit.
Note: The most important thing to remember when mounting this Rough-In Box
is that the mounting tabs must be mounted flush against the outside of the
sheetrock. This step determines whether or not the mounting stud is notched
(cutout-out to fit the Rough-In Box).
8.
9.
Replace the magnet faceplate (A in FIG. 1) back onto the main NXD unit.
Make sure to align the Microphone, Light, and PIR Motion sensor locations
to their respective openings on the front bezel/faceplate.
Pre-Wall Installation of the CP-TP17 Rough-In Box
1.
2.
3.
Measure the distance between the inside of the two selected stud beams.
Most beams have a distance of about 14" to 16". This is too narrow to
accommodate the 17.072" (43.36 cm) wide CB-TP17 Rough-In Box.
Determine whether one or both of the selected stud beams must be
mounting tabs along the outside of the post-wall sheetrock.
Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring
to their respective locations (outside the Rough-In Box) on either the AVB
breakout box, Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the PSN and apply power.
Do not use these
Cutout the notched beam using a height of 13.554" (34.43 cm) (as shown
Stud
tabs to mount
Support block
C - Optional
the Rough-In Box
Note: The determining factor in the depth of the cut into the beam is the
thickness of the drywall. The mounting tabs MUST BE FLUSH against the
drywall and therefore, the depth of the notch depends on that thickness.
Four #8 flat-head
CB-TP17
Mounting Screws
(not included)
secure the NXD to
CB-TP17
4.
Insert one side of the Rough-In Box into the indention on the notched stud
and rest the other side of the box against the opposite beam.
Install and secure a shorter horizontal beam below the Rough-In Box. This
beam acts to support the weight of the box from below and should be
secured to both vertical beams (at the sides).
5.
6.
7.
Fasten the CB-TP17 to the Notched stud/beam through the stud fastening
nails or screws.
Insert a perpendicular block between the Non-Notched stud/beam and
the Rough-In Box. This block acts as a bridge to secure the stud/beam to
the CB-TP17 along the stud fastening holes located inside of the box.
by using either nails or screws.
8.
9.
Fasten the CB-TP17 to the block through the stud fastening holes, located
10. Remove any necessary wiring knockouts from the (optional) Rough-In Box
connection to the touch panel.
Mounting Tab
B - Main NXD unit consists of
the touch panel and backbox housing
A - Faceplate
11. Thread the incoming RJ-45, Ethernet, and any other audio/video wiring
through the knockouts (use of the top or bottom knockouts are
recommended with this installation).
(bezel)
FIG. 1 Wall Mount panel installation configuration of a CB-TP17
12. Install the drywall/sheetrock before inserting the main NXD unit into the
CB-TP17.
|